Bug 64861
Summary: | Dell R820. Fail to match "ipmi_si" driver if both PNP0c01 and IPI0001 were marked for the local BMC | ||
---|---|---|---|
Product: | Drivers | Reporter: | eddy (bewantbe) |
Component: | PNP | Assignee: | Adam Belay (ambx1) |
Status: | NEW --- | ||
Severity: | normal | CC: | morgoth6, pmenzel+bugzilla.kernel.org |
Priority: | P1 | ||
Hardware: | x86-64 | ||
OS: | Linux | ||
Kernel Version: | 3.10.11 | Subsystem: | |
Regression: | No | Bisected commit-id: | |
Attachments: |
dmesg log and acpi table (acpidump)
Patch mentioned in comment |
Description
eddy
2013-11-12 15:47:59 UTC
Not sure how correct this is, but with this hint I was able to load power monitor module without any errors and it registered in hwmon! System: PowerEdge R730. -------- Adapter: ACPI interface power1: 313.00 W (interval = 2.00 s) -------- This is weird as this bug plagues all my Dell servers and if I remember correctly I saw it in one HP for years now. Patch attached. Created attachment 306012 [details]
Patch mentioned in comment
I forgot to mention, but I tested on 6.7.10 with both patched applied: - https://patchwork.kernel.org/project/linux-acpi/patch/20240320084317.366853-1-kai.heng.feng@canonical.com/ - https://patchwork.kernel.org/project/linux-acpi/patch/20240320084317.366853-2-kai.heng.feng@canonical.com/ |